Home | Contact Us | Sitemap

Our List of Products

CCTV

DVR

Access Controller

Fire Alarm  

Safety Lockers


Fire Alarm System

Avert 2 Zone to 20 Zone Model


Conception of Design

In this design the concept of sensing fire is incorporated with Smoke Detectors (Optical and Ionization in cross zone configuration) and Heat detectors as per the suitability at the site to initiate Alarm at a centrally located panel. Hooters located at strategic points will get activated to draw the attention of the inmates or the passerby in that area to identify the seat of life.

On hearing the Alarm from the hooters located at strategic points one can rush to Extinguish the fire with suitable Portable Extinguishers or through the yard hydrants depending on the nature of fire.

Description of the System / Selection of Detectors
This system shall consist of suitable detectors, Manual Call Points Hooters of High Intensity, Central Control Panel and Batteries for Standby Power. The Detectors suitably selected shall be located at Strategic Positions in the places of Fire Risk anticipated by virtue of a thorough study of the area, and shall be connected to the Main Control Panel through cables.

The Manual Call Points shall be located at places accessible for the inmates/passerby in that area, as they run out for help in the event of an emergency, located at convenient height such that any one can reach the Manual Call Point in the event of an Emergency.

The Main Control Panel shall be located at a place where the Man Power is available all the time or at least, they can reach the Main Control Panel as the Hooters go into action, so as to reach the seat of Fire in the event of an emergency.

The Hooters shall be located at strategic positions such that they go into action as the Fire is sensed by the Detectors, to draw the attention of the inmates/passerby in that area.

The batteries shall be located near the Main Control Panel, to form standby power on the event of "MAINS FAILURE".

Features:

Designed as per IS 2189 specifications

User friendly in handling the panel

SMPS power supply with inbuilt battery charger

Operation on 12v DC

16*2 LCD display to indicate zone status such as Open, loop short circuit, fir zone isolation, alarm acknowledgement and low battery.

LED indications for AC on, System on Battery, DC fuse and Charger fuse and fire

Control switches for zone isolation, alarm acknowledgement and system reset

Internal buzzer for warning -zone short, low battery and alarm acknowledged

Auto-Dialer connectivity

Hooter audibility is 90db @ 1meter

48hrs battery backup with

Easy installation and maintenance (modular type circuits boards)

Specifications:

Input voltage : 230 V A.C

Zone voltage : 12 V DC

Power consumption : 20W @ 230V A.C

Quiescent current : 70mA @ 12 V DC

Alaram current : 300mA @12 V DC
 

 